RadonTec and the EIC Accelerator: A Radon Sensor Put to the Test
Radon is a radioactive gas that seeps from the ground into buildings, and the EU project RadonTec won calls indoor radon the second most frequent cause of lung cancer. According to its CORDIS objective, more than 34 million buildings in Europe have raised radon levels. The objective argues that a compact, affordable, smart radon sensor is central to monitoring them.
RadonTec, a family business in Wittislingen, Bavaria, that has sold radon measurement and protection for years, proposed a sensor small and cheap enough to be built into ventilation units, air quality monitors and building controls. The European Innovation Council granted €1,590,750 towards a €2.27 million project. The sensor exists, is sold in RadonTec's own devices, and a university study published in 2026 supports its accuracy claim with calibration caveats. Research integrations are documented; the sources reviewed on 2 November 2026 do not establish mass-market OEM adoption.
Company file
- Legal entity
- RadonTec GmbH, Augsburg Local Court HRB 31149
- Registered
- January 2017, as Waltec GmbH
- Headquarters
- Wittislingen, Bavaria, Germany
- Managing director
- Martin Waltl (since April 2024)
- Products
- AlphaSensor module; AlphaTracer and LivAir radon monitors; radon shop and services
- Other EU funding
- €111,125 allocated in artEmis (CORDIS)
- EIC project
- AlphaSensor, 1 May 2022 to 31 Oct 2024, closed
- EIC funding
- Grant first
Where RadonTec Stands Today
RadonTec lists its sensor-based monitors through its online shop: AlphaTracer Office from €880 and an AlphaTracer Industry Serial variant at €980 including VAT, checked on 2 November 2026; prices depend on configuration. Ecosense announced a distribution partnership in January 2024. Its announcement describes RadonTec staff as trained radon experts recognised by the Bavarian Environment Agency in 2013; it does not state BfS accreditation. RadonTec separately describes itself as a state-recognised measurement provider since 2019. Recognition and laboratory accreditation should not be conflated.
RadonTec's legal notice identifies Martin Waltl as its representative and confirms Augsburg HRB 31149. The appointment dates above come from register summaries; the original register extract was not obtained for this review.
The Technology: A Lucas Cell, Shrunk
The AlphaSensor is based on the Lucas cell, a classic radon detector in which alpha particles from radon decay make a scintillating coating flash. The independent study describes it as a Lucas cell-type detector, and the CORDIS objective says the flashes are read with silicon photomultiplier (SiPM) technology. The module calculates radon concentration as a 60-minute moving average from six ten-minute measurements and reports it over a serial interface, so that other devices can use it.
The claim
Size advantages claimed in the project records
Beneficiary claims, not independently verified comparisons. A shared comparator baseline is not established. No module price comparison located in the CORDIS and product pages reviewed on 2 November 2026.
CORDIS project 190134039, objective and periodic report.
What the EIC Project Promised, and What CORDIS Shows
The EIC project
EU contribution covers 70% of the recorded project cost
AlphaSensor ran from May 2022 to October 2024.
CORDIS project 190134039. Values in € millions.
The project aimed at a sensor for mass production, to be built into building automation, heating and ventilation units and air quality monitors. The CORDIS report says the sensor gained 50% in sensitivity and is "at least 70% smaller than other solutions". The company built products around it, the AlphaTracer Industry and Office monitors and the LivAir product line, plus a cloud dashboard and interfaces for Bluetooth, WiFi, Modbus and NB-IoT, and describes the Industry monitor as IP54-rated. These are beneficiary-reported outcomes, rather than an independent certification audit. The report gives no sales, unit or customer numbers.
- A compact, accurate radon sensorDeliveredUniversity study supports accuracy; one faulty unit excluded and individual calibration recommended.
- Connected productsDeliveredAlphaTracer and LivAir lines, cloud dashboard, multiple interfaces.
- 60% cheaper than other sensorsNot shownNo module comparison located in the CORDIS and product pages reviewed on 2 November 2026.
- Mass-market integration by other manufacturersNot shownResearch integrations documented below; commercial OEM volumes not established in the reviewed sources.
The Independent Test
In February 2026 researchers at Plovdiv and Sofia universities published a 43-module study in Sensors. It reports Bulgarian recovery-plan funding and no declared conflicts. The authors support the manufacturer's 10% uncertainty claim, but excluded a faulty low-sensitivity unit, replaced without charge, from most analyses; another unit showed electronic noise. Mean relative sensitivity after that exclusion was 0.959. Table 2 gives a mean best-fit lag of 26.1 minutes relative to AlphaGUARD. Individual calibration is recommended; rapid measurements and research use have limitations. This is evidence under the tested conditions, not a guarantee for every unit or application.
The independent test
Mean relative sensitivity after excluding a faulty unit
42 units in this analysis; AS03 excluded. Sensitivity is not the calibration-factor range. A mean close to 1 does not mean every unit met the accuracy claim.
Terziyski, Tsankov and Tenev, Sensors, February 2026.
The record
From radon consultancy to sensor maker
RadonTec began as a family radon services and retail business before the EIC funded its own sensor.
- 2013Radon expertsRecognised as trained radon experts by the Bavarian Environment Agency, per Ecosense
- Jan 2017Company registeredAs Waltec GmbH, Augsburg register; later renamed RadonTec GmbH
- Jun 2021EIC Accelerator cut-offAlphaSensor: a small, fast, connected, affordable radon sensor
- May 2022EIC project starts30-month project to industrialise the sensor€1.59M grant
- Jan 2024Ecosense distribution dealRadonTec's shop starts selling Ecosense's consumer radon monitors
- Oct 2024EIC project closesBeneficiary reports AlphaTracer and LivAir products, cloud dashboard and IP54-rated Industry monitor
- Feb 2026Independent test43 AlphaSensor modules checked against a reference monitor in Bulgaria
Company history and legal notice, register summaries, Ecosense, CORDIS and Sensors.
The Money
CORDIS records an AlphaSensor EU contribution of €1,590,750 against €2,272,500 total cost. These are project funding figures, not a payment audit. For the separate artEmis consortium, CORDIS lists €111,125 for RadonTec. Neither amount establishes the company's total financing or cash balance.
What cannot be checked
The CORDIS report, product pages and scientific papers reviewed on 2 November 2026 do not establish annual AlphaSensor production or commercial OEM sales volumes. A 2025 cave-monitoring paper does describe AlphaSensor inside METER.AC instruments, so integration beyond RadonTec's own monitors is documented. Research deployment does not establish mass-market sales.
Why Europe Should Care
EU radiation protection law requires member states to set reference levels for indoor radon and to plan how to reduce exposure. Cheap, continuous sensors built into ventilation and building systems would make that measurable at scale, and a European maker of such sensors is a natural partner for Europe's HVAC and building technology industry.
What the project promised
A small, fast, connected, affordable radon sensor for mass production and integration into other devices.
What the record shows
Sensor-based products, university testing and METER.AC research integrations; mass-market volumes are not established by the sources reviewed on 2 November 2026.
The Verdict
The sensor works; the scale is unproven
The university study supports the accuracy claim under its test conditions, with faulty-unit exclusions and calibration caveats. Products and external research integrations exist. The sources reviewed on 2 November 2026 do not establish commercial OEM volumes or completion of every industrialisation objective; that evidence gap does not prove that scale-up failed.
RadonTec has not been asked for comment for this article. It is based entirely on public records, company statements, independent research and EU project data, linked throughout.
Sources
- CORDIS, AlphaSensor fact sheet and periodic report
- Terziyski, Tsankov and Tenev, Sensors, February 2026 (PMC)
- Ecosense, distribution partnership, January 2024
- radonshop.com, AlphaTracer Office and AlphaTracer Industry
- North Data, RadonTec GmbH
- CORDIS, artEmis; 2025 cave-monitoring study; company legal notice
Industry
Climate and environmentEnvironmental monitoring
AlsoElectronics and semiconductorsSensors
- Focus
- Air quality monitoring
- Imaging and radiation sensors
- Technologies
- Radiation detection
- Keywords
- Radon
- Indoor air quality
- Lung cancer prevention
- Smart buildings